Over-discharge Low Voltage Disconnect  Board Battery Charger Protection 30A 6-48v  (10005418)

6-48V 30A

Description:
YX830 is a over-discharge protection display module. The load is automatically disconnected when the battery is under voltage, and is automatically connected when the battery is over voltage.

Feature:
Suitable for 6V-48V batteries
Battery over-discharge protection
Charging protection
Support set parameters
Real-time display voltage
Automatic recovery function
Parameter power-off memory function
Load delayed power-off protection

Parameters:
Model: YX830
Control Voltage: 6V~60V
Voltage Accuracy: 0.1V
Control Current: 30A(MAX)
Scope of Application: Storage Batteries or Lithium Batteries
Work Temperature: -25℃~85℃
Work Humidity: 5%~95%RH
Size: 84*52.5*24mm

Button Setting:
Under the setting value is normal(the display is flashes),press the Start Button is increase the voltage value, press the Stop Button is decrease the voltage value.
Set under voltage start-up voltage value: In the voltage display state. In the voltage display state, short press the start button to display the under voltage start voltage. Long press the start button. After the display flashes, set the value of the under voltage start voltage by press the start button and stop button.
Set under voltage stop voltage value: In the voltage display state, short press the stop button to display the under voltage stop voltage. Long press the stop button. After the display flashes, set the value of the under voltage stop voltage through the start button and the stop button.
Restore the factory settings: In the normal startup state, press and hold the start and stop buttons at the same time, the display shows "888",indicating that the factory settings have been successfully restored.
Setup problem: When the start value cannot be increased, adjust the stop value first.
Delay description: Delay description: For example, connect a 12V battery and set the load stop voltage to 10.5V.When the battery is lower than 10.5V,the battery resumes the 10.5V load and keeps working within 6 seconds, and the battery stops working when the battery is lower than 10.5V within 6 seconds.
Load automatic switch-on instructions: For example, connect a 12V battery and set the load stop voltage to 10.5V.After the load stops, the battery recovers the voltage to 10.6V to 14.4V,and the load works.(10.6V to 14.4V recovery voltage is set by yourself)
This section is suitable for use within the voltage range of 6V and 60V.The maximum support for battery use is 48V.Because the 48V battery is fully charged at about 60V,the module will burn out at the highest. If the battery is higher than 48V,please choose another module.
The product has a 6-second time delay to avoid disconnecting the load when the battery voltage drops when the large battery starts.


Package Contents:
1pcs Over-discharge Protection Display Module